When the user triggers an alarm condition on the TOOCAA L2, the laser output is automatically switched off.

Warning Sound Identify

 Hidden Meaning

1 short beep

Trigger limit switches

2 short beeps

Opening the shield during laser processing

3 short beeps

USB lock not detected

4 short beeps

No laser module connected

Long 1 beep, short 1 beep

Machine tilt detected

Long 1 beep, short 2 beeps

Power supply mismatch

Long 1 beep, short 3 beeps

TF card abnormality during laser processing

Long 1 beep, short 4 beeps

Flame detected in working area